WOOD CHIP AND PELLET BOILER
150 – 550 kW
- Sturdy construction
- Industrial model
Wood chip and pellet boiler
Turbomat
Froling’s Turbomat is a unique heating system with a fully automatic wood burner which will operate with a wide variety of wooden material. As a leading manufacturer of biomass heating systems, the Turbomat embodies all of Froling’s expertise in pioneering innovation. We were looking for a boiler that would be perfectly suited for burning other biomass fuels as well as wood chips.
The Turbomat not only boasts innovative combustion technology but also offers impressive control options. With Lambda controls as standard, combustion chamber temperature monitoring and under-pressure control, perfect combustion is guaranteed for a range of materials. The comfort provided sets new standards in this performance category.
All Turbomat functions are fully automatic, from fuel feed and combustion right through to cleaning and ash removal. The high-tech Turbomat is designed to be extremely robust, durable and easy to service.
Information/advice
You would like to have further product information or you have general questions regarding our company?
The latest technology
TM 150/200/250
Vertical 3-pass heat exchanger and Efficiency Optimisation System WOS)
with automatically operated turbulators for cleaning and for minimal dust emissions (<50 mg/Nm³)
Flue gas recirculation FGR
optimises burning (output, emissions etc.) with particularly demanding fuels, e.g. pellets, shavings, miscanthus etc...
Speed-regulated and function-
monitored induced draught fan
together with the under-pressure
controller ensure that the system
continuously adapts to changes in
fuel and the chimney conditions
Trapezoidal stoker duct
guarantees minimal energy consumption in the feed area and full flexibility for varying fuel sizes. The industry standard drive gear unit is durable and mechanically isolated from the feed channel.
This prevents the screw movements from affecting the gear unit.
A bonus feature of the TM 200/250 is also the fact that the feed area is water-cooled in the high temperature range. This serves the very practical purpose of pre-drying the heating material where the fuel has a high moisture content.
4-layer high temperature combustion chamber
(firebrick / insulation 1 / air jacket / insulation 2) made of premium, heat-resistant fireclay components for optimal combustion, even with inferior fuel (e.g. high moisture level etc.) or alternative fuel
Multilayer thermal insulation guarantees minimum radiant heat
Large, solid combustion chamber doors
ensure ease of access for maintenance
Moving grate
for constantly homogeneous combustion process with ongoing removal of combustion residue
Automatic ash removal
for transport into adjacent ash containers
TM 320 / 400 / 500
Vertical, patented 4-pass heat exchanger
with integrated suction cyclone unit dust separation unit and Efficiency Optimisation System (WOS) with automatic cleaning function. Operating pressure up to 6 bar.
Flue gas recirculation FGR
optimises burning (output, emissions etc.) with particularly demanding fuels, e.g. pellets, shavings, miscanthus etc...
Speed-regulated and function-monitored
induced draught fan
together with the under-pressure controller ensure that the system continuously adapts to changes in fuel and the chimney conditions
Trapezoidal stoker duct
guarantees minimal energy consumption in
the feed area and full flexibility for varying fuel sizes. The industry standard drive gear unit is durable and mechanically isolated from the feed channel. This prevents the screw movements from affecting the gear unit. A
bonus feature is also the fact that the feed area is water-cooled in the high temperature
range. This serves the very practical purpose of pre-drying the heating material where the fuel has a high moisture content.
Second ignition fan
for heating material that is hard to light (e.g. damp)
Second ignition fan
for heating material that is hard to light (e.g. damp)
Case cooling of combustion chamber minimises radiant heat
High-temperature post combustion
zone
with hot fireclay lining prolongs combustion. This increases efficiency even further, particularly with inferior fuels.
4-layer high temperature combustion chamber (firebrick / insulation 1 / air jacket / insulation 2) made of premium, heat-resistant fireclay components for optimal combustion,
even with inferior fuel (e.g. high moisture level etc.) or alternative fuel
Large, solid combustion chamber doors
ensure ease of access for maintenance
Moving grate for constantly homogeneous combustion process with ongoing removal of combustion residue.
The innovative primary air zone separation system produces exceptional combustion results with low CO emissions!
Systematic convenience
Mit der Kesselregelung geht Fröling in die Zukunft. Das intelligente Regelungsmanagement besteht aus hochwertigen Komponenten des Industriestandards und bietet eine Vielzahl von Einstellungs- und Visualisierungsmöglichkeiten für den individuellen, effizienten und stabilen Anlagenbetrieb. Die Bedieneinheit bietet zahlreiche Funktionsmöglichkeiten wie 5-Fühler-Pufferspeichermanagement, Heizkreis-bzw. Netztemperaturregelung, externe Leistungsvorgabe, Kaskadenfunktion, Einbindung, Überwachung und Steuerung zusätzlicher Umfeldkomponenten.
Advantages
Powerful controller with big colour touch display
Safe and simple remote access via Froling visualisation software
Numerous functional possibilities
Brochures / EU Label
Technical specifications
Technical specifications - Turbomat | 150 | 200 | 250 | 320 | 400 | 500 | 550 |
---|---|---|---|---|---|---|---|
Nominal heat output [kW] | 150 | 199 | 250 | 320 | 399 | 499 | 550 |
Flue pipe diameter [mm] | 200 | 250 | 250 | 300 | 350 | 350 | 350 |
Total dry weight including attachments [kg] | 3300 | 3820 | 3820 | 6330 | 8470 | 8470 | 8470 |
Heat exchanger water capacity [l] | 440 | 570 | 570 | 780 | 1040 | 1040 | 1040 |
Maximum permitted operating temperature [°C] | 90 | 90 | 90 | 90 | 90 | 90 | 90 |
Minimum boiler return temperature [°C] | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
Maximum permitted working over-pressure [bar] | 4 | 4 | 4 | 6 | 6 | 6 | 6 |
Flue gas temperature (NL / PL) [°C] | 150/110 | 150/110 | 150/110 | 140 / 110 | 140 / 110 | 140 / 110 | 140 / 110 |
Dimensions
Dimensions - Turbomat [mm] | 150/200/250 | 320 | 400/500/550 |
---|---|---|---|
H1 Boiler height including insulation | ~#i#~ | 2560 | 2660 |
H2 Height of return connection | ~#i#~ | 640 | 710 |
H3 Height of flow connection | ~#i#~ | 1850 | 2000 |
H4 Height of stoker including burn back protection system | ~#i#~ | 815 | 930 |
H5 Height, flue gas pipe connection without FGR | ~#i#~ | 960 | 985 |
H6 Height, flue gas pipe connection with FGR | ~#i#~ | 2005 | 2075 |
B Total width including fittings | ~#i#~ | 2780 | 2990 |
B1 Width, boiler including insulation | ~#i#~ | 2195 | 2495 |
B2 Width, combustion chamber ash containere | ~#i#~ | 730 | 1165 |
L Total length including fittingse | ~#i#~ | 3340 | 3595 |
L1 Length, stoker unit | ~#i#~ | 940 | 1050 |
L2 Length, combustion chamber ash container | ~#i#~ | 600 | 630 |
Technical documentation
For you personally
Information & advice
You would like to have further product information or you have general questions regarding our company?