PELLET FUELLED CONDENSING BOILER
16 – 22 kW
Integrated particle separator
(electrostatic precipitator)
available as an option
Pellet fuelled condensing boiler
PE1c Pellet
The newly developed PE1c pellet-fuelled condensing boiler is fitted with innovative condensing technology as standard. This new technology ensures even higher efficiency and exceptionally quiet operation within a very compact design. In addition the new PE1c Pellet scores well for high convenience, low emissions and low power consumption.
Information/advice
You would like to have further product information or you have general questions regarding our company?
The latest technology
Connection for operation independent of room air
Lambda probe for optimised combustion
Optional integrated particle separator (electrostatic precipitator) for even lower emissions
Stainless steel condensing heat exchanger with automatic flushing
High-quality insulation
WOS system efficiency optimisation system for automatic cleaning of the heat exchanger
Air-cooled heat exchanger casing for maximum efficiency and low surface temperatures
7“ touch display with LED status indication for simple and intuitive operation
Boiler of stainless steel for maximum service life
High-quality pellet burner with power-saving ceramic igniter
Automatic slide valve for fully automatic ash clearance and cleaning
Generously-sized ash container for long intervals between emptying
Individual control unit of the heating system
Lambdatronic 3200 control unit
Fröling provides a future-oriented Lambdatronic 3200 and a new 7“ touch display. Intelligent control management makes it possible to connect up to 18 heating circuits, up to 4 storage tanks and up to 8 hot water storage tanks. The control unit ensures that the operating statuses are clearly shown. The menu structure is ideally organised to allow easy operation. All essential functions can be selected by simply pressing icons on the large colour display.
Advantages:
- Precise combustion control by a Lambda control using a Lambda probe
- Connection for up to 18 heating circuits, 8 water heaters and up to 4 storage tank management systems
- Integration capability for a solar panel system
- LED frame for status display with illuminated presence detection
- Simple and intuitive operation
- Various smart home options (such as Loxone)
- Remote control from the living room (remote control 3200 and RGB 3200 Touch) or via Internet (froeling-connect.com)
Keep track of everything with the Froling App
The Froling App allows you to check and control your Froling boiler online from
anywhere, at any time. You can read and modify the main status information and settings easily and conveniently online. You can also specify which status messages you want to be informed about via SMS or e-mail (e.g. when the ash box is to be emptied or in the event of a fault message).
The app is available in the Android Play Store and iOS App Store.
Advantages
- Simple and intuitive operation of the boiler
- Status information can be called up and changed within seconds
- Individual naming of the heating circuits
- Changes of status are notified directly to the user (e.g. via
e-mail or push notifications) - No additional hardware required (such as an Internet gateway)
Smart Home
Loxone
Combine your Froling heating system with the Loxone Miniserver and the new Froling Extension and implement individual boiler control on the basis of the single room control of the Loxone Smart Home.
Modbus
Via the Froling modbus interface, the system can be integrated
into a building management system.
Brochures / EU Label
Technical specifications
Technical data | 16 | 22 |
---|---|---|
Nominal heat output [kW] | 15 | 20 |
Nominal thermal output (condensation) [kW] | 16,2 | 22 |
Thermal output range [kW] | 4,5 - 15 | 6 - 20 |
Thermal output range (condensation) [kW] | 4,8 - 16,2 | 6,4 - 22 |
Energy (ErP) label | A++ | A++ |
Electrical connection [V/Hz/A] | 230V / 50Hz / abgesichert C16A | 230V / 50Hz / abgesichert C16A |
Weight of boiler (including stoker, without water) [kg] | 370 | 375 |
Total boiler capacity (water) [l] | 75 | 75 |
Pellet container capacity [l] | 60 | 60 |
Ashcan / ash box capacity [l] | 18 | 18 |
Condensate per nominal load hour [l] | 1,0 - 1,5 | 1,8 - 2,2 |
Necessary water pressure for the flushing device [bar] | 2 | 2 |
Dimensions
Dimensions [mm] | 16-22 |
---|---|
L Length of boiler | 780 |
L1 Total length incl. flue gas pipe connection | 810 |
L2 Clearance at the flue gas pipe connection side | 126 |
L3 Clearance at the condensate drain side | 90 |
L4 Clearance flow / return | 70 |
B Width of boiler | 750 |
B1 Width of boiler incl. distributor bar for three pump assemblies (A)¹ | 820 |
B2 Clearance for the flue gas pipe connection at the back | 234 |
B3 Clearance for the condensation drain at the back | 167 |
B4 Clearance from the return to the boiler | 168 |
B5 Clearance from the flow to the return | 90 |
H Height of the boiler / connection for the suction system / connection for the flushing water | 1500 |
H1 Height of the flow connection / return | 1525 |
H2 Height of the flue gas pipe connection | 450 |
H3 Height of the condensation drain connection | 220 |
H4 Height of the drainage connection | 335 |
H5 Height of the boiler incl. distributor for three / two pump assemblies (A)1 | 2005 |
Flue spigot diameter (inner) | 132 |
¹ For an optional pump assembly with distributor
Operating and maintenance areas
Minimum distances [mm] | 16-22 |
---|---|
A Distance – front of boiler to wall | 550 |
B Distance between side of boiler and wall | 500 |
C Clearance between the rear of boiler and the wall (flue gas pipe back)¹ | 400 |
C1 Clearance between the rear of boiler and the wall (flue gas pipe right)² | 100 |
D Clearance between the rear of boiler and the wall (door stop side) | 30 (70) |
E Maintenance area above the boiler | 500 |
Minimum space (length x width) | 1360 x 1280 |
¹ Rear flue pipe connection
² Fit the flue pipe connection to the right-hand side of the boiler